codekasten/led-satellite/hardware/satellites/schematic/small_satellite-controller.sch

197 lines
3.6 KiB
Text
Raw Normal View History

v 20081231 1
C 40000 40000 0 0 0 title-B.sym
C 45900 46500 1 0 0 attiny24-1.sym
{
T 48150 49350 5 10 1 1 0 6 1
refdes=uC
T 45500 50650 5 10 0 0 0 0 1
device=ATTINY24
T 45500 50850 5 10 0 0 0 0 1
footprint=DIP14
T 44900 49100 5 10 1 1 0 0 1
net=VCC_uC:1
T 48700 49100 5 10 1 1 0 0 1
net=GND_uC:14
}
C 41500 46600 1 0 0 switch-dip8-2.sym
{
T 41800 49350 5 10 1 1 0 0 1
2009-12-18 18:58:37 +01:00
refdes=CONF
T 41500 46600 5 10 0 0 0 0 1
footprint=HEADER16_2
}
C 51500 48800 1 0 0 connector2-1.sym
{
T 51700 49800 5 10 0 0 0 0 1
device=CONNECTOR_2
T 51500 49600 5 10 1 1 0 0 1
refdes=POWER_IN
2009-12-18 18:58:37 +01:00
T 51500 48800 5 10 0 0 0 0 1
2009-12-18 23:38:08 +01:00
footprint=HEADER2_1
T 51500 48800 5 10 0 0 0 0 1
net=VCC_HIGH:1
T 51500 48800 5 10 0 0 0 0 1
net=GND_LED:2
}
C 55500 48800 1 0 1 connector2-1.sym
{
T 55300 49800 5 10 0 0 0 6 1
device=CONNECTOR_2
T 55500 49600 5 10 1 1 0 6 1
refdes=POWER_OUT
2009-12-18 18:58:37 +01:00
T 55500 48800 5 10 0 0 0 0 1
2009-12-18 23:38:08 +01:00
footprint=HEADER2_1
T 55500 48800 5 10 0 0 0 0 1
net=VCC_HIGH:1
T 55500 48800 5 10 0 0 0 0 1
net=GND_LED:2
}
N 53200 49000 53800 49000 4
N 41500 47000 41500 48500 4
{
T 41500 47200 5 10 1 1 90 0 1
netname=GND_uC
}
N 53200 49300 53800 49300 4
C 53300 44700 1 0 0 connector6-2.sym
{
T 54000 47600 5 10 1 1 0 6 1
refdes=COMM_BUS
T 53600 47550 5 10 0 0 0 0 1
device=CONNECTOR_6
T 53600 47750 5 10 0 0 0 0 1
2009-12-18 18:58:37 +01:00
footprint=SIP6
}
N 48600 47100 53300 47100 4
{
T 52900 47100 5 10 1 1 0 0 1
netname=SCL
}
N 45900 46700 45900 46200 4
N 45900 46200 51200 46200 4
N 51200 46200 51200 46700 4
N 51200 46700 53300 46700 4
{
T 52900 46700 5 10 1 1 0 0 1
netname=SDA
}
2009-12-19 01:50:21 +01:00
N 48600 48300 49600 48300 4
{
T 48600 48300 5 10 1 1 0 0 1
2009-12-18 18:58:37 +01:00
netname=VCC_HIGH
}
2009-12-19 01:50:21 +01:00
N 48600 47900 49600 47900 4
{
T 48600 47900 5 10 1 1 0 0 1
2009-12-18 18:58:37 +01:00
netname=CURRENT_CONTROL_LOW
}
N 42800 49100 45900 49100 4
N 41500 49100 40400 49100 4
{
T 40400 49100 5 10 1 1 0 0 1
netname=VCC_HIGH
}
N 42800 48800 43600 48800 4
{
T 42800 48800 5 10 1 1 0 0 1
netname=PWM_uC
}
N 44300 48700 45900 48700 4
{
T 44300 48700 5 10 1 1 0 0 1
netname=MASTER_SLAVE
}
N 45000 47900 45900 47900 4
{
T 45000 47900 5 10 1 1 0 0 1
netname=PWM_uC
}
N 44300 48700 44300 48500 4
N 42800 48500 44300 48500 4
N 41500 48800 40400 48800 4
{
T 40400 48800 5 10 1 1 0 0 1
netname=PWM_LED
}
N 53300 45100 53300 45900 4
{
T 53300 45100 5 10 1 1 90 0 1
netname=GND_uC
}
N 42800 48200 44600 48200 4
N 44600 48200 44600 48300 4
N 44600 48300 45900 48300 4
{
T 44700 48300 5 10 1 1 0 0 1
netname=uC_CONF_A
}
N 42800 47900 44600 47900 4
N 44600 47900 44600 47500 4
N 44600 47500 45900 47500 4
{
T 44700 47500 5 10 1 1 0 0 1
netname=uC_CONF_B
}
N 42800 47600 44400 47600 4
N 44400 47600 44400 47100 4
N 44400 47100 45900 47100 4
{
T 44700 47100 5 10 1 1 0 0 1
netname=uC_CONF_C
}
N 42800 47300 44000 47300 4
{
T 42800 47300 5 10 1 1 0 0 1
netname=uC_CONF_D
}
N 48600 46700 49800 46700 4
{
T 48600 46700 5 10 1 1 0 0 1
netname=uC_CONF_D
}
2009-12-19 01:50:21 +01:00
N 48600 47500 51000 47500 4
{
T 48600 47500 5 10 1 1 0 0 1
2009-12-19 01:50:21 +01:00
netname=SENSOR_IN
}
N 48600 48700 50300 48700 4
{
T 48600 48700 5 10 1 1 0 0 1
netname=uC_CONF_SERIAL
}
N 53300 46300 51600 46300 4
{
T 51600 46300 5 10 1 1 0 0 1
netname=uC_CONF_SERIAL
}
T 50000 40700 9 10 1 0 0 0 1
Small Satellite - uC
T 50100 40100 9 10 1 0 0 0 1
1
T 51600 40100 9 10 1 0 0 0 1
2
T 54000 40400 9 10 1 0 0 0 1
1
T 54000 40100 9 10 1 0 0 0 1
Lars Kruse <devel@sumpfralle.de>
2009-12-19 01:50:21 +01:00
C 49900 50300 1 270 0 3tri-1.sym
{
T 50600 49900 5 10 0 0 270 0 1
device=3TRI
T 50500 49900 5 10 1 1 270 0 1
refdes=MOVEMENT_SENSOR
T 49900 50300 5 10 0 0 270 0 1
footprint=SIP3
}
N 45900 49100 45900 50200 4
N 45900 50200 49900 50200 4
N 49900 49900 49900 49100 4
N 49900 49100 48600 49100 4
N 51000 47500 51000 50100 4
N 51000 50100 50800 50100 4
N 42800 47000 44000 47000 4
{
T 42800 47000 5 10 1 1 0 0 1
netname=SENSOR_IN
}